VF and NL series motorized control valves

All categories
VF and NL series motorized control valves

1½ ″ - 10 ″

Ductile iron motorized control valves of VF730/750 and NL800/870 series apply to HVAC and building automation systems. Once the motorized control valves receive signals transmitted by computers or other devices, they can then adjust temperature, pressure and control system parameters such as flow rate and liquid level. The valves are mainly used to convey mediums such as cold water, hot water, and ethylene glycol solution.

Classification: Motorized Control Valves
PDF

PDF

Product Features

Adopt the AC synchronous hysteresis clutch motor. When the limited position is reached, the hysteresis clutch disengages the motor's output shaft from the transmission part to protect the motor.

High-precision control offers precise actions.

Low power consumption and low noise.

Have the self-adaptive valve travel function.

Multiple signal controls: Increment/floating-point signal, voltage 0 - 10 V, current 4 - 20 mA.

ABS shell and die-cast aluminum bracket with the advantages of small size and light weight.

Easy installation and maintenance.

Technical Parameters

Valve Type:Two-way Valve/three-way Valve

Material:Shell:ductile iron; disc/stem: stainless steel;Sealing: PTFE

Working Pressure:1.6 Mpa/2.5 Mpa

Medium:cold water, hot water, and the aqueous solution of ethylene glycol (concentration within 50%)

Medium Temperature:-10℃ ~ 120℃/-10℃ ~ 180℃ with a heat sink

Flow Characteristic:Equal percentage curve/equivalent linear

Leakage Volume:Below 0.02% of kv value

End Type:Flanges (ANSI B16.1/16.5 or EN1092)

Actuator Parameters
Item Performance parameters
Model VF series(incremental control model) NL series (proportional adjustment model)
Power Supply AC24VAC/220VAC±10%,50Hz/60Hz
Motor AC synchronous motor
Force 1000N,1500N,3000N
Power Consumption 6-18VA
Operating Speed 1¼″-2″ 0.20 mm/s (1000 N)2½″ 0.25 mm/s (1500 N)4″-8″ 0.32 mm/s (3000 N)
Control Signal Increment/floating-point signal 0~10VDCor4~20mA
Working Temperature -10°C~50°C(50°F~120°F)
Humidity 10%~90%RH,no condensation
Maximum Travel 1000N 22mm;1500N 22mm;3000N 55mm;6500N 60mm;10000N 100mm
Actuator Weight 1000N 2.7Lbs/1.2kg; 1500N 3.3Lbs/1.5kg; 3000N 7.7Lbs/3.5kg
Materials Of Main Parts Fire-retardant ABS plastic shell and die-cast aluminum bracket
Waterproof Rating IP54
Valve Opening Before Delivery Middle position
Manual Function Have manual operation
Valve Opening Indication Have valve open ingindication
Insulation Resistance Resistance between the power supply terminal and the shell:≥50MΩ; that between the input terminal and the shell:≥20MΩ.
Dielectric Strength

Dielectric strength between the power supply terminal and the shell:500V,50 Hz for AC24V equipment;

1,500 V,50Hz for AC220 equipment; that between the input terminal and the shell:500 V,50 Hz


Dimensions
VF and NL series motorized control valves VF and NL series motorized control valves
In 2 3 4 5 6 8 10
mm 40 50 65 80 100 125 150 200 250
L 200 230 290 310 350 400 480 495 622
H Two-way valve 165 175 215 235 265 295 320 405 489
Three-way valve 242 259 273 291 323 363 395 492 643
H1 Two-way valve 329 332 333 344 421 437 451 475 938
Three-way valve 329 332 333 344 421 437 451 475 938
H2 Two-way valve 79 86 125 134 154 168 179 240 241
Three-way valve 156 170 183 190 212 236 254 327 395
D 150 165 185 200 220 250 295 340 405
K 110 125 145 160 180 210 240 295 355
Number of flangeholes
and number of bolts
4-M16 4-M16 4-M16 8-M16 8-M16 8-M16 8-M20 12-M20 12-M24
Flow Direction of Medium
VF and NL series motorized control valves
Note: Please note that the flow direction of the medium in pipelines is the same as the direction of the valve body's arrow during design and installation.

Kv (Flow Rate Value) and Close-Off Differential Pressure
In 2 3 4 5 6 8 10
mm 40 50 65 80 100 125 150 200 250
Kv value (m³/h) 21 35 52 88 140 200 280 410 630
Close-off differential pressure (MPa) 0.47 0.3 0.4 0.3 0.35 1 1 1 0.2
Force 1000N 1500N 3000N 6500N

Note: The closed-off pressure differential listed in this table refers to the calibration value when the medium is water at 25°C.

Electrical Wiring Diagrams
VF and NL series motorized control valves
Note: The power switch must be closed during the normal operation of the actuator, and it is strictly forbidden to run the actuator when it is not connected to the valve body.
HVAC Valves